Alert |
Count |
Station ID |
Age |
By |
Alert message |
|
retry |
13 |
042 - NUDE2 |
09:40 |
sonpoll |
?could not connect to ip modem...retry 1 |
|
alert |
7 |
042 - NUDE2 |
09:39 |
sonpoll |
?unable to open ipmodem ... skipped |
|
connect |
5 |
042 - NUDE2 |
09:39 |
sonpoll |
?too many retries connecting to ip modem...abort |
- 2025044+1416 (acknowledged, hmahlke)
-
bat :
2025023+1730,2025041+2200 (01/23/2025 17:30 - 02/10/2025 22:00) :
battery voltage dropping. Edited for time correction and to note something fuckey going on. Batt voltage and water depth are eerily similar in values and trending the same. More in depth investigation needed, but most likely needs panel and regulator. EDIT: I believe parameter listing of the sensor is incorrect and depth is reading the sensor battery voltage
- 2025044+1417 (active, hmahlke)
-
dth :
2025041+2200,now (02/10/2025 22:00 - 02/16/2025 08:05) :
water depth is zero. Everything else looks good
Station water depth is an imprecise measurement. It is based on mounting the sensor approximately 9 inches from seafloor and adjusting data based on a contemporaneous lead line measurement.
|
 |
 |