Daily Quality Control
16 Feb 2025 08:05 UTC 2025047+08:05 UTC
Overview Datums Bench Marks Data Query Site Visit Daily QC Messages Attributes
042: Nueces Delta 2

27° 53' 19" N   97° 34' 10" W
NUDE2
The Coastal Bend Bays & Estuaries Program Coastal Bend Bays and Estuaries Program

Previous (033) - QC Station List - Next (051)

Alerts

  Alert Count Station ID Age By Alert message
noise retry 13 042 - NUDE2 09:40 sonpoll ?could not connect to ip modem...retry 1
alert alert 7 042 - NUDE2 09:39 sonpoll ?unable to open ipmodem ... skipped
alert connect 5 042 - NUDE2 09:39 sonpoll ?too many retries connecting to ip modem...abort

Messages

2025044+1416 (acknowledged, hmahlke)
bat : 2025023+1730,2025041+2200 (01/23/2025 17:30 - 02/10/2025 22:00) :

battery voltage dropping. Edited for time correction and to note something fuckey going on. Batt voltage and water depth are eerily similar in values and trending the same. More in depth investigation needed, but most likely needs panel and regulator. EDIT: I believe parameter listing of the sensor is incorrect and depth is reading the sensor battery voltage

2025044+1417 (active, hmahlke)
dth : 2025041+2200,now (02/10/2025 22:00 - 02/16/2025 08:05) :

water depth is zero. Everything else looks good

Previous (033) - QC Station List - Next (051)
Station water depth is an imprecise measurement. It is based on mounting the sensor approximately 9 inches from seafloor and adjusting data based on a contemporaneous lead line measurement.
Page last modified on May 15, 2009, at 10:09 AM
Texas A&M-University Corpus Christi Texas A&M University-Corpus Christi
T h e    I s l a n d    U n i v e r s i t y
6300 Ocean Drive, Corpus Christi, Texas 78412-5503
Privacy Statement